Resultados 1 - 16 de 16
Filtrar
1.
J Interv Card Electrophysiol ; 61(3): 603-607, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32860605

RESUMO

PURPOSE: This study was designed to evaluate the electromagnetic interference (EMI) effects and safety of the new security screening millimetre wave body scanners (MWBSs) for patients with rare cardiac implantable electronic devices (CIEDs). METHODS: We identified 73 patients with either entirely subcutaneous implantable cardioverter-defibrillators (S-ICD) or leadless pacemakers (LPM) attending routine device follow-up. CIED programming was optimised for the detection of EMI occurrence, and high-voltage therapy was disabled. Patients then underwent millimetre wave body scans under continuous ECG monitoring. Scanning was performed at the recommended distance as well as in close proximity to the scanner emulating accidental exposure. CIED function was observed for EMI effects. RESULTS: There were no episodes of inhibition of pacing in the leadless pacemaker subgroup, no oversensing in the S-ICD subgroup and no spontaneous device reprogramming in any group. There was no change in pacing or sensing thresholds, and S-ICD vector eligibility remained unchanged after scanning with the MWBS. No CIEDs were identified by the MWBS during the study. CONCLUSION: No EMI events were detected during the use of MWBSs by patients with either S-ICDs or LPMs. This data should be reassuring for patients suggesting that they can undergo security body scans without worries or disclosure of their CIED status.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Eletrocardiografia , Humanos , Tela Subcutânea
4.
Clin Res Cardiol ; 108(10): 1117-1127, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30874886

RESUMO

AIMS: In the IN-TIME trial, automatic daily implant-based multiparameter telemonitoring significantly improved clinical outcomes in patients with chronic systolic heart failure and implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D). We compared IN-TIME results for ICD and CRT-D subgroups. METHODS: Patients with LVEF ≤ 35%, NYHA class II/III, optimized drug treatment, no permanent atrial fibrillation, and a dual-chamber ICD (n = 274) or CRT-D (n = 390) were randomized 1:1 to telemonitoring or no telemonitoring for 12 months. Primary outcome measure was a composite clinical score, classified as worsened if the patient died or had heart failure-related hospitalization, worse NYHA class, or a worse self-reported overall condition. RESULTS: The prevalence of worsened score at study end was higher in CRT-D than ICD patients (26.4% vs. 18.2%; P = 0.014), as was mortality (7.4% vs. 4.1%; P = 0.069). With telemonitoring, odds ratios (OR) for worsened score and hazard ratios (HR) for mortality were similar in the ICD [OR = 0.55 (P = 0.058), HR = 0.39 (P = 0.17)] and CRT-D [OR = 0.68 (P = 0.10), HR = 0.35 (P = 0.018)] subgroups (insignificant interaction, P = 0.58-0.91). CONCLUSION: Daily multiparameter telemonitoring has a potential to reduce clinical endpoints in patients with chronic systolic heart failure both in ICD and CRT-D subgroups. The absolute benefit seems to be higher in higher-risk populations with worse prognosis.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Insuficiência Cardíaca Sistólica/terapia , Volume Sistólico/fisiologia , Telemedicina/métodos , Idoso , Causas de Morte/tendências , Feminino , Seguimentos , Alemanha/epidemiologia , Insuficiência Cardíaca Sistólica/mortalidade , Insuficiência Cardíaca Sistólica/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Resultado do Tratamento
5.
Int J Cardiol ; 228: 784-789, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27898337

RESUMO

OBJECTIVE: Evidence on cardiac resynchronization therapy (CRT) in older patients is scarce and conflicting. Nevertheless, CRT in the elderly is of major practical relevance as heart failure prevalence increases with age. METHODS: The German Device Registry (DEVICE) is a nationwide, prospective registry with a longitudinal follow-up design investigating device implantations in 60 German centres. The present analysis of DEVICE focussed on perioperative complication rates and 1-year outcome of patients ≥75years (n=320) compared to younger patients (n=879) receiving a CRT device. RESULTS: Comorbidities were more common in older patients (chronic kidney disease (CKD): 27.5% vs. 21.5%, p=0.029; atrial fibrillation (AF): 26.9% vs. 15.6%, p<0.001). Despite higher NYHA classes in the older age group, ejection fractions were comparable (27.2±7.1% ≥75years, 26.2±7.1% <75years, p=0.06). Perioperative complications and mortality rates did not show significant difference between groups. After new device implantation, absolute 1-year mortality was higher in older patients (11.0% ≥75years, 6.4% <75years, p=0.014), with a significantly lower proportion of cardiac deaths in the older group (p=0.05). Patients ≥75years being alive after 1year had lower response rates, with chronic kidney disease (OR 0.46, p<0.05) and smaller QRS complexes (OR 0.31, p<0.01) being particular risk factors for missing improvement of heart failure symptoms. As expected severe heart failure (NYHA IV) was a strong independent predictor of death (HR 1.95, p=0.01), whereas AF as underlying rhythm could be worked out as predictor for mortality especially in the younger patients (HR 2.31, p=0.002). CONCLUSIONS: Patients ≥75years of age receiving a CRT device do not have a higher perioperative mortality and complication rate although comorbidities (CKD and AF) occur more frequently. The absolute 1-year mortality is higher; nevertheless, the proportion of cardiac deaths is even lower in the older patients reflecting a benefit of CRT in this group.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Complicações Intraoperatórias/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Alemanha/epidemiologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Prevalência , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
7.
Sci Rep ; 6: 21748, 2016 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-26892534

RESUMO

The programming of implantable cardioverter-defibrillators (ICDs) influences inappropriate shock rates. The aim of the study is to analyse rates of patients with appropriate and inappropriate shocks according to detection zones in the OPTION trial. All patients received dual chamber (DC) ICDs randomly assigned to be programmed either to single chamber (SC) or to DC settings including PARAD+ algorithm. In a post-hoc analysis, rates of patients with inappropriate and appropriate shocks were calculated for shocks triggered at heart rates ≥ 170 bpm (ventricular tachycardia zone) and at rates ≥ 200 bpm (ventricular fibrillation zone). In the SC group, higher rates of patients with total and inappropriate shocks were delivered at heart rates ≥ 170 bpm than at rates ≥ 200 bpm (total shocks: 21.1% vs. 16.6%; p = 0.002; inappropriate shocks: 7.6% vs. 4.5%, p = 0.016; appropriate shocks: 15.2% vs. 13.5%; p = n.s.). No such differences were observed in the DC group (total shocks: 14.3% vs. 12.6%; p = n.s.; inappropriate shocks: 3.9% vs. 3.6%; p = n.s.; appropriate shocks: 12.2% vs. 10.4%; p = n.s.). The higher frequency of patients with total shocks with SC settings than with DC settings that benefit from PARAD+ was driven by a higher percentage of patients with inappropriate shocks in the VT zone (170-200 bpm) in the SC population.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Taquicardia Ventricular/terapia , Idoso , Algoritmos , Morte Súbita Cardíaca , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Software , Resultado do Tratamento
8.
Europace ; 17(4): 584-90, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25567067

RESUMO

AIMS: Intracardiac electrograms (IEGMs) are essential for the assessment of implantable cardioverter-defibrillator (ICD) function. The Biotronik Home Monitoring systems transmit an 'IEGM Online' that is shorter than the full-length programmer IEGM due to technical constrains. The aim of this study was to evaluate the accuracy of the physician's classification of the underlying rhythm based on the second-generation IEGM Online. METHODS AND RESULTS: In total, 1533 patients treated with single- and dual-chamber ICDs and cardiac resynchronization therapy defibrillators were enrolled at 67 investigational sites and followed for 15 months. The investigators classified the rhythm shown in IEGM Online as ventricular tachycardia, ventricular fibrillation, atrial fibrillation, other supraventricular tachyarrhythmia, oversensing due to lead failure, T-wave oversensing, or other rhythm. At the next in-office follow-up, the investigators classified independently the rhythm seen in the corresponding programmer IEGM. The two rhythm classifications were compared thereafter. Both IEGM Online and programmer IEGM were available in 2099 arrhythmic or oversensing events, of which 146 (7.0%) were classified as other rhythm or artefacts and were excluded as inconclusive or atypical. The remaining 1953 events, affecting 352 patients (23.0%), were classified correctly in 1803 cases (92.3%). The accuracy of rough rhythm classification as ventricular, supraventricular, or oversensing was 97.2%. CONCLUSION: The Lumax and IEGM Online HD Evaluation study demonstrates that remote IEGM analysis is reasonably accurate in a remote monitoring system that transmits shorter IEGM than the full-length programmer IEGM for the sake of frequent, fully automatic data transmission.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Eletrocardiografia/métodos , Telemedicina/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sistemas On-Line , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Interface Usuário-Computador
9.
JACC Heart Fail ; 2(6): 611-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25282033

RESUMO

OBJECTIVES: The OPTION (Optimal Anti-Tachycardia Therapy in Implantable Cardioverter-Defibrillator Patients Without Pacing Indications) trial sought to compare long-term rates of inappropriate shocks, mortality, and morbidity between dual-chamber and single-chamber settings in implantable cardioverter-defibrillators (ICDs) patients. BACKGROUND: The use of dual-chamber ICDs potentially allows better discrimination of supraventricular arrhythmias and thereby reduces inappropriate shocks. However, it may lead to detrimental ventricular pacing. METHODS: This prospective multicenter, single-blinded trial enrolled 462 patients with de novo primary or secondary prevention indications for ICD placement and with left ventricular ejection fractions ≤40% despite optimal tolerated pharmacotherapy. All patients received atrial leads and dual-chamber defibrillators that were randomized to be programmed either with dual-chamber or single-chamber settings. In the dual-chamber setting arm, the PARAD+ algorithm, which differentiates supraventricular from ventricular arrhythmias, and SafeR mode, to minimize ventricular pacing, were activated. In the single-chamber setting arm, the acceleration, stability, and long cycle search discrimination criteria were activated, and pacing was set to VVI 40 beats/min. Ventricular tachycardia detection was required at rates between 170 and 200 beats/min, and ventricular fibrillation detection was activated above 200 beats/min. RESULTS: During a follow-up period of 27 months, the time to the first inappropriate shock was significantly longer in the dual-chamber setting arm (p = 0.012, log-rank test), and 4.3% of patients in the dual-chamber setting group compared with 10.3% in the single-chamber setting group experienced inappropriate shocks (p = 0.015). Rates of all-cause death or cardiovascular hospitalization were 20% for the dual-chamber setting group and 22.4% for the single-chamber setting group and satisfied the pre-defined margin for equivalence (p < 0.001). CONCLUSIONS: Therapy with dual-chamber settings for ICD discrimination combined with algorithms for minimizing ventricular pacing was associated with reduced risk for inappropriate shock compared with single-chamber settings, without increases in mortality and morbidity. (Optimal Anti-Tachycardia Therapy in Implantable Cardioverter-Defibrillator [ICD] Patients Without Pacing Indications [OPTION]; NCT00729703).


Assuntos
Fibrilação Atrial/terapia , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Supraventricular/terapia , Fibrilação Atrial/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Taquicardia Supraventricular/mortalidade , Resultado do Tratamento
16.
J Mol Biol ; 354(3): 520-8, 2005 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-16253275

RESUMO

Oxa1 is the mitochondrial representative of a family of related proteins that mediate the insertion of substrate proteins into the membranes of bacteria, chloroplasts, and mitochondria. Several studies have demonstrated that the bacterial homologue YidC participates both in the direct uptake of proteins from the bacterial cytosol, and in the uptake of nascent proteins from the Sec translocase. Studies on the biogenesis of membrane proteins in mitochondria established that Oxa1 has the capability to receive substrates at the inner surface of the inner membrane. In this study, we asked if Oxa1 may similarly cooperate with a protein translocase within the membrane. Since Oxa1 is involved in its own biogenesis, we used the precursor of Oxa1 as a model protein and investigated its import pathway. We found that immediately after import into mitochondria, Oxa1 initially accumulates at Tim23 that forms the inner membrane protein translocase. Cleavage of the Oxa1 presequence is dependent on mtHsp70, a heat shock protein of the mitochondrial matrix. However, mutant mtHsp70 showing a defect in the release of bound substrate proteins does not interfere with subsequent membrane insertion, indicating that membrane insertion of the mature protein is essentially mtHsp70-independent. We conclude that Oxa1 has the ability to accept preproteins within the membrane.


Assuntos
Complexo IV da Cadeia de Transporte de Elétrons/metabolismo , Membranas Intracelulares/metabolismo , Mitocôndrias/metabolismo , Proteínas Mitocondriais/metabolismo , Proteínas Nucleares/metabolismo , Complexo IV da Cadeia de Transporte de Elétrons/genética , Proteínas de Choque Térmico HSP70/genética , Proteínas de Choque Térmico HSP70/metabolismo , Proteínas de Membrana Transportadoras/metabolismo , Mitocôndrias/genética , Proteínas do Complexo de Importação de Proteína Precursora Mitocondrial , Proteínas Mitocondriais/genética , Peso Molecular , Mutação/genética , Proteínas Nucleares/genética , Ligação Proteica , Saccharomyces cerevisiae/genética , Saccharomyces cerevisiae/metabolismo , Proteínas de Saccharomyces cerevisiae/metabolismo